Testing and verification

HAMSTAD benchmark validation

Completed comparisons of the GenBuildings HAMT solver with analytical solutions and published benchmark results.

Assessment date: 29 October 2026GenBuildings HAMT solver: Modified EnergyPlus HAMT with driving-rain transport

Benchmark overview

Introduction to HAMSTAD

HAMSTAD is a set of five numerical benchmark cases for checking how building-physics software models heat and moisture transport through building materials. The cases compare calculated responses with analytical solutions or published results from other simulation tools.

Each case examines a different construction or transport process. Together, they help identify which parts of a solver have been evaluated and where further testing is needed.

  1. Case 1 — Insulated roof

    Examines how moisture redistributes between a load-bearing layer and insulation over repeated annual cycles.

  2. Case 2 — Isothermal moisture redistribution

    Tests moisture transport at a constant temperature by comparing simulated profiles with an analytical solution.

  3. Case 3 — Transport with airflow

    Examines heat and moisture carried by air moving through porous material. This mechanism is outside the evaluated GenBuildings solver scope.

  4. Case 4 — Coupled heat and rain transients

    Tests a brick-plaster assembly exposed to changing thermal and moisture conditions, including rain.

  5. Case 5 — Capillary-active interior insulation

    Examines moisture redistribution through a multilayer wall with interior insulation, including the moisture profile near material interfaces.

Scope of the GenBuildings assessment

The completed work covers four HAMSTAD cases under their documented numerical configurations. Case 3 requires through-material airflow and is outside the evaluated solver scope. The original benchmark programme defines five one-dimensional heat, air and moisture cases. Original publication →

Analytical comparison

Case 2 compares simulated moisture profiles with a Fourier-series solution.

Graphical comparison

Cases 1, 4 and 5 compare responses with published participant figures, subject to the report’s qualifications.

Numerical conservation

Moisture-balance checks assess numerical consistency; they do not establish physical certification.

Results at a glance

GenBuildings HAMSTAD assessment · 29 October 2026
CaseTestAssessment
1Insulated roofVery good graphical agreement
2Isothermal moisture redistributionStrong analytical agreement
3Transport with airflowNot evaluated
4Heat and rain transientsVery good graphical agreement
5Interior insulationVery good graphical agreement

Case-by-case results

Benchmark cases

01
Completed · very good graphical agreement

Insulated roof

This case tests how moisture moves between a roof’s load-bearing layer and its interior insulation over five years.

GenBuildings results are compared with published HAMSTAD reference curves. The plots below show the first and fifth years using the same baseline configuration.

ExteriorInterior · 20°C
Vapour sealExterior boundary
Load-bearing layer100 mm
Insulation50 mm
Schematic cross-section; not to scale.
Test conditions
Duration5 repeated annual cycles
Initial state10°C; load-bearing layer 145 kg/m³; insulation 0.065 kg/m³
Boundary conditionsVapour-sealed exterior with changing equivalent temperature; interior at 20°C with prescribed vapour pressure
Rain and solarNo rain or direct solar input; exterior equivalent temperature supplies thermal forcing

First year

First-year layer moisture compared with published HAMSTAD participant results.
First-year moisture response compared with published HAMSTAD results.

Fifth year

Case 1 benchmark comparison reproduced from page 4 of the completed report
Fifth-year moisture response compared with published HAMSTAD results.

The comparison is graphical and remains qualified; it is not a formal pass against numerical acceptance limits.

02
Completed · strong analytical agreement

Isothermal moisture redistribution

Boundary · 45% RHBoundary · 65% RH
Homogeneous material200 mm
Schematic cross-section; not to scale.
Test conditions
TemperatureConstant 20°C
Initial humidity95% RH
Boundary humidity45% and 65% RH
Comparison times100, 300 and 1,000 hours

Results

Case 2 benchmark comparison reproduced from page 8 of the completed report
Moisture profiles against the analytical solution at 100, 300 and 1,000 hours.
Errors against the analytical solution
TimeMaximum point water errorTotal water error
100 h0.008044 kg/m³0.000538 kg/m²
300 h0.004051 kg/m³0.000461 kg/m²
1,000 h0.001754 kg/m³0.000362 kg/m²

Assessment: strong analytical agreement under the prescribed isothermal conditions. Small retained vapour permeability and finite surface resistance distinguish the numerical setup from the analytical limit.

03
Not evaluated · outside solver scope

Transport with airflow

This benchmark requires air-pressure-driven transport through porous material, including changes in flow direction. The evaluated solver covers conduction, vapour diffusion and liquid transport, but not the required through-material advective coupling.

Pressure boundaryPressure boundary
Porous materialAirflow through the material ↔
Conceptual transport schematic; this case was not simulated.
Test conditions
Process testedHeat and moisture transport with pressure-driven airflow
AirflowChanges in flow direction
GenBuildings statusNot evaluated; required airflow coupling is outside the assessed solver scope

Assessment: not evaluated. Airflow through the material requires additional solver capability.

04
Completed · very good graphical agreement

Coupled heat and rain transients

Exterior · rain exposureInterior
BrickLoad-bearing layer
PlasterFinishing layer
Schematic cross-section; not to scale.
Test conditions
Duration120 hours
ConstructionBrick and plaster
Boundary conditionsTime-varying temperature and vapour-pressure schedules, with rain exposure
Compared outputsSurface temperature and moisture histories

Moisture response

Case 4 benchmark comparison reproduced from page 11 of the completed report
Surface moisture histories against published participant curves, using the documented timing interpretation.
Wall water at 120 h
18.807879 kg/m²
Integrated moisture residual
2.669 × 10−7 kg/m²

Assessment: very good graphical agreement. The calculation uses a documented boundary-timing interpretation, including a first temperature pulse ending at 79 hours. No formal numerical pass is claimed.

Temperature response

Surface and interface temperatures compared with published HAMSTAD participant results.
Surface and interface temperatures compared with published HAMSTAD participant results.
05
Completed · very good graphical agreement

Capillary-active interior insulation

Exterior · 0°C / 80% RHInterior · 20°C / 60% RH
Brick365 mm
Mortar15 mm
Insulation40 mm
Schematic cross-section; not to scale.
Test conditions
Duration60 days
Initial state25°C and nominal 60% RH
Boundary conditionsExterior 0°C / 80% RH; interior 20°C / 60% RH
Rain and solarNone

Results at 60 days

Case 5 benchmark comparison reproduced from page 12 of the completed report
Water-content and relative-humidity profiles at 60 days. The visible reference range is not an acceptance band.
Peak water content
63.244 kg/m³
Total wall water at 60 days
2.702001 kg/m²

The peak falls within the approximate published 60–64 kg/m³ graphical range. The RH reference is the digitized HAMSTAD average from van Schijndel et al. (2017), not the HAM-BC 2015 curve.

Assessment: very good graphical agreement. The assessment remains provisional. Digitized curves are not formal acceptance limits; full timestep sensitivity and an energy-budget check remain outstanding.

Conclusion

GenBuildings shows very good graphical agreement for the insulated roof, heat and rain transients, and interior insulation cases, together with strong analytical agreement for isothermal moisture redistribution.

These comparisons demonstrate the evaluated solver’s performance across different heat and moisture transport scenarios. Case 3, which requires airflow through porous materials, remains outside the evaluated scope.

Reference sources

Primary references.